Leica disto error 220

Leica 3D Disto Manual Online: Error Messages. Error No. Advice 150 Working range was exceeded. 151 Invalid measurement. 152 Change the 3D Disto position or use ruler for offset points. 160 Repeat and do not move the ruler between both measurements. 161 In some cases the Offset Point...

7

Error messages and

advice

1.800.561.8187

3D Disto, Error Messages

Error No. Advice

150

Working range was exceeded.

151

Invalid measurement.

152

Change the 3D Disto position or use ruler for offset points.

160

Repeat and do not move the ruler between both measurements.

161

In some cases the Offset Point tool can not be used.

170

Restart 3D Disto if the problem persists.

171

Check all devices, for example power supply or cables, and try again.

240

Tilt sensor calibration was not successful. System accuracy is at risk.

Contact your distributor or Leica Geosystems representative.

241

Too much drift. Repeat calibration precisely.

243

Set up the instrument stably. Do not touch or rotate the 3D Disto. Repeat

calibration.

300

Select a horizontal line.

350

Check projection surface. Laser could not reach the correct position.

755

Point cannot be measured. Try different position. Tool does not work on

horizontal planes.

760

Point cannot be measured. Enter different values. Tool does not work on

horizontal planes.

765

Point cannot be measured. Try different position or enter different value.

Tool does not work on horizontal planes.

800

Data import or export is not possible.

801

Not enough memory on USB stick.

802

Storage device does not work properly.

803

Check file condition and content.

804

File or Folder write-protected or damaged.

900

3D Disto error. Contact your distributor or Leica Geosystems representa-

tive if the error repeats.

901

The reflected laser signal is too low.

902

The reflected laser signal is too high.

903

Too much background light.

904

Laser beam interrupted. Repeat measurement.

950

Execute Location Check to retain accuracy!

951

3D Disto tilt is over 3°. Set up horizontally!

952

Check 3D Disto, check for obstacles interrupting WLAN connection, or

move towards 3D Disto.

953

Check connection and cable.

954

Plug in cable or choose «WLAN» in the menu.

955

3D Disto temperature out of working range.

956

Too much vibration or permanent movement.

998

Contact your distributor or Leica Geosystems representative.

999

Contact your distributor or Leica Geosystems representative.

www.

information@itm.com

.com

62

Error  Code

Description

Corrective Measure

154

Transverse tilt >20°

Hold the instrument without any transverse tilt

156

Transverse tilt > 10°

Hold the instrument without any transverse tilt

160

Main tilt direction, angle too high (>45°)

Measure angle up to +/- 45°

162

The calibration has not been

accomplished on a leveled

surface and the calibration value

is respecitvely within an ineligible

area.

Calibrate the device on an absolute

horizontal leveled surface.

203

Wrong measuring sequence for Pythagoras measurements

Measure in correct sequence

204

Calculation error

Repeat procedure

206

No endpiece detection

Attach the endpiece properly. If error still occurs, replace the endpiece

217

Measuring module error

   Contact Us

240

Data transfer error

Repeat procedure

245

2nd button pressed although no

Bluetooth connection exists.

Establish Bluetooth connection

252

Temperature too high, above 50°C

Cool down the instrument

253

Temperature too low, below 0°C

Warm up instrument

255

Receiver signal too low, measuring time too long, distance too long

Use target plate, measuring time > 10 sec.

256

Receiver signal too strong

Use target plate (white side)

257

Erroneous measurement, too much   backlight

Use target plate

260

Laser beam was interrupted

Repeat measurement

272-276

 Measuring module error

Contact Us

279

 Measuring module error

   Contact Us

285-291

 Measuring module error

   Contact Us

297-299

 Measuring module error

   Contact Us

402

 Measuring module error

   Contact Us

404

 Measuring module error

   Contact Us

501-503

 Measuring module error

   Contact Us

651

 Measuring module error

   Contact Us

801-803

 Measuring module error

   Contact Us


Добро пожаловать!

Войдите или зарегистрируйтесь сейчас!

Войти


  1. А.н.д.р.е.й

    У меня проблемы с измерениями: при нажатии кнопки ALL или DIST выдает ошибку 255 (будто исходящий сигнал не вернулся). Однако при проведении EDM теста, качество сигнала не ниже 95%, видимость прямая — помех нет. В чем дело, я не знаю..

    #1


  2. А.н.д.р.е.й

    Народ, ну хоть предположения какие-нибудь есть?

    #2


  3. Kostyuk

    Форумчанин

    Регистрация:
    3 июн 2009
    Сообщения:
    207
    Симпатии:
    15
    Адрес:

    Москва

    В почту ответил.
    Продублирую ответ здесь:

    Добрый день!

    Рекомендуем обратиться в авторизованный сервис.
    Возможно, Вам потребуется настройка дальномера или замена платы дальномера.

    #3


  4. А.н.д.р.е.й

    Все дело,как оказалось, в плате дальномера… Ремонт обошелся в 35 тысяч рублей…

    #4

Поделиться этой страницей

Понравилась статья? Поделить с друзьями:

Читайте также:

  • Lego movie videogame как изменить разрешение
  • Lego marvel superheroes как изменить разрешение экрана
  • Lego marvel superheroes вылетает после 1 миссии как исправить
  • Lego marvel super heroes ошибка 0xc0000142 как исправить
  • Lego batman 3 error

  • 0 0 голоса
    Рейтинг статьи
    Подписаться
    Уведомить о
    guest

    0 комментариев
    Старые
    Новые Популярные
    Межтекстовые Отзывы
    Посмотреть все комментарии